Yes : ✔ No : ✖ Good : ●●● Fair : ●● Poor : ● |
GENERAL CONDITION |
ET Download Available | ✔ |
Machine Starts and is Operable | ✔ |
Tires are Aired Up and Drivable | ✔ |
GENERAL APPEARANCE |
Cleaning Required | ✔ |
SAFETY ITEMS |
Back Up Alarm Functioning | ✔ |
Brakes Functioning | ✔ |
ROPS | ✔ |
GAUGES, OPERATOR STATION, CONSOLE |
Back Up Alarm | ✔ |
ROPS Certification Plate | ✔ |
ENGINE |
Blow By | ✔ |
EPA Decal | ✔ |
Fluid Levels OK? | ✖ |
Fuel Leaks | ✔ |
Knocking | ✖ |
Oil Leaks | ✖ |
Water in Oil | ✖ |
COOLING SYSTEM |
Leaks - COOLING SYSTEM | ✖ |
Oil in Anti-Freeze | ✖ |
ELECTRICAL, STARTING AND CHARGING SYSTEM |
Block Heater | ✔ |
Ether Aid | ✔ |
TRANSMISSION |
Leaks - TRANSMISSION | ✖ |
Mag Screens Checked | ✖ |
Transmission - Noisy | ✖ |
STEERING |
Articulate P & B | ●●● |
Hand Metering Unit | ●●● |
Lines / Fittings - STEERING | ●●● |
Steering Cylinder | ●●● |
Steering Linkage | ●● |
Steering Valves / Pumps | ●●● |
Steering Wheel Tilt / Extend | ●●● |
BRAKE |
Holds In Park | ✔ |
HYDRAULICS |
Leaks - HYDRAULICS | ✔ |
ATTACHMENTS / WORK TOOLS |
Leaks - HYDRAULICS | 45-150 Paralift by Denharco grapple system, loader arm by grapple tilting cylinders on R&L sides rewelded and cracking through the welds, R&L grapple by the cylinder rod mounts welded, cracking through the welds, all in good operational condition |
FINAL DRIVES |
Leaks - FINAL DRIVES | ✖ |
TIRES |
Leaks - FINAL DRIVES | 89 |
Leaks - FINAL DRIVES | 26.5R25 |
COMMENTS, MISC. REPAIRS, GENERAL REMARKS |
Leaks - FINAL DRIVES | Engine has excessive smoke, rear axle pivot, |